Basic Principle and Application of Water Chiller

2019-07-16

Chillers are divided into air-cooled chillers and water-cooled chillers in the industry. Chillers are divided into cryogenic chillers and normal-temperature chillers in temperature control. Normal temperature is generally controlled in the range of 0-35 degrees. The temperature control of cryogenic machine is generally in the range of 0 - 100 degrees below zero.


Working Principle of Water Chiller for Cooling Water Equipment with Constant Temperature, Current and Pressure


First, a certain amount of water is injected into the water tank of the machine, and then the water is cooled by the cooling system of the water cooler. Then the low-temperature cooling water is fed into the equipment to be cooled by the water pump. The chiller chilled water takes away the heat, then the temperature rises and returns to the water tank to achieve the cooling effect.


In air-conditioning systems, chilled water is usually distributed to heat exchangers, or coils are cooled in the air-handling units, or other types of terminal equipment in their respective spaces (S-air), and then the cooling water is redistributed back to the cooled. These cooling coils transfer sensible heat and latent heat from air to chilled water, so dehumidifying cooling air flow is usually used. A typical air conditioning unit uses refrigeration capacity rated at 15 to 1500 tons (180,000,18,000,000 British heat units/h or 53 to 5,300 kilowatts). The temperature range of frozen water ranges from 35 to 45 degrees Fahrenheit or from 1.5 to 7 degrees Celsius, depending on the application requirements.


circulatory system


The liquid refrigerant in the evaporator absorbs the heat in the water and begins to evaporate in the refrigerant recycling system of the water cooler. The temperature difference between the final refrigerant and the water forms. The liquid refrigerant is also completely evaporated into gaseous state and then inhaled and compressed by the compressor. The gaseous refrigerant absorbs heat through the condenser and condenses into liquid. After throttling, the superheated expansion valve becomes a low temperature and low pressure refrigerant and enters the evaporator to complete the refrigerant recycling process.


When shaping products of water chiller, due to the variety of raw materials, the size and shape of the shaping products are different, the clamping force required is also different. Please adjust the clamping force according to the minimum required. In this way, the power consumption can be saved and the service life of the machine can be significantly prolonged.


Industrial water chiller must pay attention to the safety of operation when using the machine. At the beginning of each operation, please check the reliability of the safety device, safety rod and safety door of the machine. During the operation of the machine, remember not to put your hand into the clamping mechanism. When taking products, we must open the safety door, after confirming personnel safety and no foreign body in the mould, we can close the safety door. In addition, in operation, the hand can not reach between the nozzle and the die gate. When repairing the mould, please turn off the oil pump motor.


Screw chiller has the advantages of high efficiency, good performance, low noise, low vibration, energy saving, high reliability and long service life. According to customer's needs and cold tonnage size, single or multi-unit combination is adopted. Compressors can rotate alternately automatically according to load changes, balancing the running time of each compressor, greatly prolonging the service life of chillers. Use industry 1. Selection of the size of special water chiller for injection moulding machine is the need for 25HP water chiller when used for cooling of injection moulds. When used for cooling other equipment, it depends on the specific flow rate of cooling water circulation. 2. The selection of the heat preservation tank and pump of the water cooler sometimes follows the actual situation of the customer's factory. The power requirement of the open water cooler is the same as that of the box water cooler of the same type when the external water pump is connected. 3. The return water temperature of the chiller should not be higher than 40 degrees. The higher the return water temperature, the greater the damage to the compressor.



主站蜘蛛池模板: 免费无码毛片一区二区app| 免费a级毛片在线播放不收费| 精品无码人妻一区二区三区不卡| 亚洲av色香蕉一区二区三区| 手机看片福利一区二区三区| 精品国产污污免费网站| 国产国产精品人在线视| 性一交一乱一色一视频| 精品久久久久久国产潘金莲| 最爽无遮挡行房视频| 国产强奷伦奷片| 国产三级精品三级在线观看| 亚洲欧美日韩国产精品专区| 免费大片黄在线观看| 国产妇女馒头高清泬20p多| 熟妇人妻va精品中文字幕| 人妻少妇精品无码专区| 亚洲国产美女精品久久久久∴| 久久99精品久久久久子伦| 久久er热在这里只有精品66| 亚洲av无码国产精品色软件| 美女脱了内裤打开腿让男人戳| 免费a级黄毛片| 三叶草欧洲码在线| 中文国产成人精品久久不卡| 亚洲欧洲无卡二区视頻| 亚洲精品自产拍在线观看| 狼狼综合久久久久综合网| 免费久久99精品国产自在现线| 领导边摸边吃奶边做爽在线观看 | 日韩午夜理论免费tv影院| 无码少妇一区二区| 人妻无码久久精品| 亚洲男人的天堂在线播放| 国产一区二区三区乱码| 豆国产96在线 | 亚洲| 亚洲av午夜福利精品一区二区| 亚洲av日韩av在线电影天堂| 最新亚洲人成网站在线观看| av无码网址| 黑人巨大精品欧美一区二区免费|